Resources & Information

Tank Heating Done Quickly and Efficiently. Contact Thermal Products To See How!

Learn how Thermal Products can assist you with your quick tank heating needs to your fully customized tank heating needs for all types of fluids.

Application:
In 1998 the Environmental Protection Agency (EPA) ruled that owners of Underground Storage Tanks must conform to standards that were established for secondary containment. Secondary containment tank is a tank assembly consisting of a primary tank and an integral outer secondary containment means capable of being monitored for leakage. EPA required all Underground Storage Tanks to be retrofitted to meet secondary containment requirements, removed or replaced by Above Ground Storage Tanks. Many State Agencies have indicated the use of Above Ground Storage Tanks is the best option. Above-ground Storage Tanks are usually installed outdoors which can lead to problems when the product viscosity is affected by colder temperatures. The solution is to add a heater to warm the product and maintain a free flowing viscosity.

Design Requirements:
An 8,000 gallon rectangular Above-ground Storage Tank filled with diesel fuel was installed at a major airport in the U.S. With a design outside winter temperature of ‐20ºF and 10 MPH winds a heater is required to maintain the fuel at 40ºF. Since no openings were allowed in the side of the tank the only access for the heater was through the top of the tank. Using the new INDEECO I‐HEAT heater selection program it was quickly determined that a 2 KW immersion heater would be required.

Solution:
INDEECO selected an over‐the‐side flanged deep tank immersion heater with a remote industrial control panel. The heater used was a 3‐inch 150# carbon steel flange and 0.475 diameter steel elements rated at 6 watts per square inch. The 46‐inch long heating elements were mounted to a 76‐inch riser which positioned the elements in the lower half of the tank. The heater was furnished with both high limit and temperature control thermocouples.

One of INDEECO’s standard NEMA 4X industrial control panels equipped with a main power disconnect switch, controlling contactor, transformer, digital thermostat, Type J thermocouple controller, status pilot light and 150 watt enclosure heater was selected to control the heater.

INDEECO Advantages:
The customer was looking for a quick solution. INDEECO was able to offer a quick-ship standard industrial panel. The custom heater’s lead‐time was 5‐weeks and the panel was available in 2‐weeks.

Contact Thermal Products to see how we, with INDEECO can assist you with all your tank heating needs

Written by Indeeco